Feem ntau cov chaw kho dej khib nyiab hauv nroog (WWTPs) hauv Suav teb siv cov txheej txheem aerobic lom kom tshem tawm cov organic teeb meem, nitrogen, phosphorus, thiab lwm yam kuab paug los ntawm cov dej khib nyiab. Kev muab cov pa oxygen yaj (DO) hauv dej yog qhov yuav tsum tau ua ua ntej rau kev tswj hwm microbial lub neej xav tau thiab kev kho mob zoo hauv cov txheej txheem aerobic lom. Yog li ntawd,chav tsev aeration yog lub hauv paus ntawm kev kho cov dej khib nyiab aerobic. Ib txhij, lub aeration system kuj yoglub zog tseem ceeb -siv unitnyob rau hauv WWTPs, accounting rau45% mus rau 75% ntawm tag nrho cov nroj tsuag siv zog. Dhau li ntawm kev ua haujlwm, kev siv lub zog aeration yog cuam tshuam los ntawm cov yam ntxwv xws li dej khib nyiab zoo thiab ib puag ncig. Feem ntau cov cheeb tsam hauv Suav teb muaj plaub lub caij sib txawv, cov dej nag ntau, thiab qhov kub ntawm lub caij hloov pauv tseem ceeb. Cov dej nag lub caij ntuj sov dilutes qhov muaj kuab paug siab concentration ntawm WWTPs, thaum lub caij ntuj no kub tsis tshua muaj cuam tshuam rau microbial kev ua si, yog li cuam tshuam rau cov dej tsis zoo. Cov kev hloov pauv hauv cov dej ntws zoo thiab qhov ua tau zoo kuj ua rau muaj kev sib tw rau kev tswj xyuas meej ntawm lub tshuab aeration hauv WWTPs. Yog tias tsis muaj kev nkag siab txaus ntawm cov kev hloov pauv hauv cov pa oxygen hloov pauv ntawm cov npuas dej zoo thiab lawv cov kev saib xyuas thaum lub sijhawm ua haujlwm, qhov zoo ntawm cov pa oxygen hloov pauv siab (OTE) ntawm cov tshuab ua npuas zoo tsis tuaj yeem siv tag nrho, ua rau lub zog pov tseg.

 

Hom siv dav tshaj plaws tam sim no yog lubzoo npuas diffuser, uas nws qhov kev ua tau zoo yog ncaj qha ntsig txog kev ua haujlwm ntawm lub zog siv lub tshuab aeration. Cov txheej txheem rau kev ntsuas cov pa oxygen hloov pauv ntawm cov npuas ua kom zoo muaj xws li kev sim zoo li qub (xws li kev ntsuas dej huv) thiab kev ntsuas tsis muaj zog (xws li kev tawm- qauv ntsuas roj). Kev tshawb fawb ntawm cov kev ntsuam xyuas zoo li qub feem ntau tsom rau kev sim- ntsuas ntsuas ntsuas, thaum cov txheej txheem ntsuas dynamic tsis tshua muaj tshwm sim vim muaj yam xws li qhov yuav tsum tau ua ntawm qhov chaw sim thiab cov kev txwv hauv cheeb tsam. Tam sim no, Tuam Tshoj tsuas yog tsim cov qauv tsim nyog rau txoj kev ntsuas dej huv. Thaum lub sijhawm ua haujlwm tiag tiag, cov pa oxygen hloov pauv ntawm cov diffusers cuam tshuam los ntawm cov yam ntxwv xws li kev ua tau zoo, cov yam ntxwv sludge, cov haujlwm ua haujlwm, thiab diffuser fouling. Qhov kev ua tau zoo sib txawv ntawm qhov ntsuas dej huv, ua rau muaj kev sib txawv loj heev thaum siv cov ntaub ntawv dej huv los kwv yees qhov xav tau ntawm huab cua tiag tiag. Qhov tsis muaj kev saib xyuas zoo rau kev ua haujlwm aeration zog kev ua haujlwm hauv WWTPs ua rau lub zog pov tseg. Yog li ntawd, nws yog ib qho tsim nyog los ntsuas thiab ntsuas qhov kev hloov pauv oxygen ntawm cov diffusers thaum lub sijhawm ua haujlwm tiag tiag los qhia kev hloov kho raws sijhawm ntawm cov tswv yim aeration thiab pab ua kom tau txais kev txuag hluav taws xob thiab kev txo qis hauv aeration systems. Txoj kev tshawb no yuav siv sij hawmib lub nroog WWTP hauv Shanghai ua piv txwv. Los ntawm kev ntsuas cov pa phem nyob rau hauv lub tank aerobic thiab cov qauv kev hloov pauv ntawm OTE raws txoj hauv kev ntawm lub tshuab ua npuas dej zoo nyob rau lub caij ntuj sov thiab lub caij ntuj no, cov pa phem tshem tawm thiab kev ua haujlwm aeration system tau ntsuas thiab ntsuas. Lub hom phiaj yog txhawm rau tshawb nrhiav qhov cuam tshuam ntawm kev hloov pauv raws caij nyoog ntawm kev hloov pauv cov pa oxygen ntawm lub tshuab aeration, muab kev taw qhia rau kev tswj xyuas meej thiab lub zog-txuag kev ua haujlwm ntawm aeration systems hauv kev kho dej khib nyiab.

 


 

1. Cov ntaub ntawv thiab cov txheej txheem

 

1.1 WWTP Kev Ua Haujlwm Txheej Txheem

Shanghai municipal WWTP ntiav cov txheej txheem ua ke ntawmpretreatment + txheej txheem AAO + tob txaj fiber ntau lim + UV tshuaj tua kab mob. CovKev kho muaj peev xwm yog 3.0 × 10⁵ m³ / d. Cov txheej txheem tseem ceeb ntawm WWTP tau qhia hauvDaim duab 1. Tus influent yog feem ntaudej phwj hauv tsev, thiab cov effluent ua tau raws li Qib A tus qauv ntawm "Txoj Cai Tso Tawm Ntawm Cov Pua Plaws rau Cov Kev Kho Dej Hauv Nroog" (GB 18918-2002) ua ntej tso tawm rau hauv Dej Yangtze. Lub sij hawm tuav hydraulic (HRT) rau lub tank anaerobic, anoxic tank, thiab aerobic tank ntawm cov roj ntsha tank hauv cov nroj tsuag no yog 1.5 h, 2.7 h, thiab 7.1 h, feem. Internal reflux ratio thiab sab nraud reflux piv yog ob qho tib si 100%. Lub hnub nyoog sludge yog tswj ntawm 10-15 hnub. Cov nroj tsuag muaj tag nrho ntawm 8 aerobic tso tsheb hlau luam. Ib lub tank aerobic ntsuas 116.8 m × 75.1 m × 7.0 m (L × W × H), nrog ntim ntawm 11,093 m³. Qhov sib xyaw cawv suspended solids (MLSS) concentration yog tswj nyob ib ncig ntawm 4 g / L. Hauv qab yog nruab nrogUkrainian Ecopolemer polyethylene tubular zoo npuas diffusers, qhov loj me ntawm 120 mm × 1,000 mm (D × L). Cov huab cua - rau - dej piv yog 5.7: 1. Txhua lub tank aerobic muaj 3 raws (Zone 1, Zone 2, thiab Zone 3). Raws li DO concentration ntsuas los ntawm cov roj ntws ntsuas hauv cov kab, cov lus qhia ntawm ib qho -theem centrifugal blowers (4 ua haujlwm, 2 standby) raug kho kom tswj tau qhov DO concentration hauv lub tank aerobic ntawm 2-5 mg / L. Txhua lub tshuab muaj qhov ntsuas cua ntws ntawm 108 m³ / min, lub siab ntawm 0.06 kPa, thiab lub zog ntawm 160 kW. Txhua channel yog tswj cais siv cov pa ntsuas ntsuas. Ua ke nrog DO nyeem cov lus tawm tswv yim, qhov tseeb huab cua yog tswj los ntawm kev kho cov lus qhia vanes ntawm ib-theem centrifugal blowers kom tswj qhov nruab nrab DO hauv lub tank aerobic ntawm 2-5 mg / L. Qhov tsim muaj txiaj ntsig / dej zoo thiab 2019 influent zoo ntawm cov nroj tsuag tau qhia hauvTable 1.

news-1050-650

news-980-500

 

1.2 Test Point Layout

Ob qhov kev ntsuam xyuas ntawm kev hloov pauv cov pa oxygen ntawm qhov zoo ntawm cov npuas aeration nyob rau hauv cov kev ua haujlwm tiag tiag tau ua thaum Lub Xya Hli (lub caij ntuj sov) thiab Lub Kaum Ob Hlis (lub caij ntuj no). Raws li kev khiav dej num, 22 cov ntsiab lus xeem tau teeb tsa raws li qhov chaw ntawm qhov chaw soj ntsuam ntawm lub tank aerobic. Qhov kev ncua deb ntawm ob qhov kev xeem uas nyob ib sab yog kwv yees li 5 m, nrog rau 7, 7, thiab 8 xeem cov ntsiab lus hauv cheeb tsam 1, Zone 2, thiab Zone 3, raws li. Kev faib cov ntsiab lus xeem tau qhia hauvDaim duab 2. Qhov tseeb OTE ntawm cov npuas zoo diffusers ntawm txhua qhov taw qhia tau suav los ntawm kev ntsuas cov pa oxygen hauv qhov tawm - pa tawm ntawm dej. Tib lub sijhawm, DO concentration thiab dej kub ntawm txhua qhov taw qhia tau ntsuas los ntawm kev siv ntau - ntsuas dej tsis zoo (HQ 30d, Hach, USA), thiab cov pa phem concentration ntawm txhua qhov taw qhia tau ntsuas thiab ntsuas kom tau txais nws cov qauv sib txawv raws txoj hauv kev. Txhawm rau tiv thaiv CODCrnyob rau hauv cov qauv ntawm degrading thaum lub sij hawm hloov, cov qauv coj raws li lub tank aerobic tau lim rau ntawm -qhov chaw ua ntej ntsuas.

news-1100-725

 

1.3 Kev ntsuas ntawm Oxygen Hloov Kev Ua Haujlwm ntawm Fine Bubble Diffusers raws li qhov tseeb

Kev ntsuas kev ua haujlwm ntawm cov pa oxygen hloov pauv ntawm cov npuas diffusers zoo nyob rau hauv cov xwm txheej tiag tiag siv qhov tawm -gas analyzer ntawm nws tus kheej tsim los ntawm Shanghai University of Electric Power, suav nrog cov khoom siv roj, kev ntsuas roj, thiab cov teeb liab hloov pauv. Tawm- roj tau sau los ntawm lub twj tso kua roj (KVP15-KM-2-C-S, Karier, Tuam Tshoj) thiab lub hood, thiab xa mus rau electrochemical oxygen sensor (A-01, ITG, Germany) rau kev tshuaj xyuas. Lub teeb liab hloov dua siab tshiab tau hloov pauv lub sensor qhov tso zis voltage teeb liab mus rau hauv cov pa ib nrab siab hauv cov pa. Thaum kuaj cov pa roj, cov pa oxygen ib feem ntawm cov huab cua puag ncig tau ntsuas ua ntej. Tom qab ntawd lub hood tau kho ntawm cov dej saum npoo ntawm lub tank aerobic kom khaws cov pa tawm thiab ntsuas nws cov pa ib nrab siab. Cov ntaub ntawv raug kaw tom qab cov zis ruaj khov rau 5 feeb. Cov kev ntsuas tau los ntawm cov khoom siv hluav taws xob tsis zoo suav nrog cov pa oxygen ib nrab siab hauv huab cua ambient thiab off-gas, los ntawm qhov feem pua ​​​​ntawm cov pa xa tawm los ntawm cov pa roj mus rau cov cawv sib xyaw, piv txwv li, OTE ntawm cov npuas npuas zoo, tau suav nrog hauvKev sib npaug (1).

 

news-553-111

Qhov twg:

Y(O,huab cua)- Cov pa oxygen hauv huab cua;

Y(O,tawm -gas)- Qhov feem ntawm cov pa tawm hauv - pa;

AOTE- Tus nqi ntawm OTE.

 

Lub OTE ntsuas los ntawm kev tawm -gas analyzer raug kho rau DO, kub, thiab ntsev kom tau tus qauv OTE (SOTE) ntawm cov npuas zoo diffuser hauv cov dej khib nyiab raws li tus qauv, xws li hauvKev sib npaug (2). Kev suav ntawm saturated DO hauv dej yog qhia hauvKev sib npaug (3).

 

news-554-185

 

Qhov twg:

θ- Kub kho coefficient, npaum li 1.024, dimensionless;

ASOTE- Tus nqi ntawm SOTE;

- Salinity coefficient rau cov cawv sib xyaw (xws li raws li tag nrho cov khoom yaj hauv cov dej cawv sib xyaw), tsis muaj qhov sib txawv, feem ntau yog 0.99;

- Qhov sib piv ntawm cov pa oxygen hloov ua haujlwm ntawm cov diffuser hauv cov dej khib nyiab piv rau cov dej huv, tsis muaj qhov loj;

C - DO concentration hauv dej, mg/L;

CS,T- Saturated DO concentration hauv dej ntawm qhov kub thiab txias T, mg/L;

CS,20- Saturated DO concentration hauv dej ntawm 20℃, mg/L;

T- Dej kub,℃.

 

1.4 Txoj kev suav rau Aeration System Kev Siv Hluav Taws Xob

Lub theoretical oxygen xav tau ntawm lub tank aerobic tau xam raws li Activated Sludge Model (ASM). Cov pa oxygen xav tau raug xam raws li CODCrthiab ammonia nitrogen tshem tawm cov txiaj ntsig los txiav txim siab tag nrho cov pa oxygen xav tau (TOD) ntawm lub tank aerobic, xws li hauvKev sib npaug (4).

Qhov twg:

MTOD- Tus nqi ntawm TOD, kg O₂/h;

Q- Tus nqi ntws zoo, m³/d;

ΔCCODCr- Qhov sib txawv ntawm qhov muaj zog thiab cov dej ntws tawm COD Cr concentration, mg/L;

ΔCAmmonia nitrogen- Qhov sib txawv ntawm qhov muaj zog thiab effluent ammonia nitrogen concentration, mg/L; 4.57 yog qhov hloov pauv ntawm ammonia nitrogen rau NO₃⁻-N.

 

Cov pa oxygen muab tus nqi ntawm qhov zoo npuas aeration system yog xam raws li nyob rau hauvKev sib npaug (5).

news-553-56

Qhov twg:

MOTR- Tus nqi ntawm cov pa oxygen tiag tiag, kg O₂/d;

QAFR- Huab cua ntws, m³/h;

ŷO₂- Feem ntau ntawm cov pa oxygen hauv huab cua, 0.276.

 

Lub tshuab hluav taws xob yog txiav txim siab los ntawm qhov tseeb huab cua ntawm lub tshuab hluav taws xob thiab lub qhov hluav taws xob siab, uas nyob rau hauv lem yog txiav txim siab los ntawm kev siv lub siab, siab poob ntawm cov pa hauv cov raj xa dej, lub siab poob ntawm cov npuas zoo ntawm nws tus kheej, thiab cov dej zoo li qub 承受 ntawm lub tank hauv qab.Kev sib npaug (6).

Qhov twg:

news-553-194

ρhuab cua- Cua ceev, g/L, npaum li 1.29 g/L;

N - Blower zog, kW;

R- Universal gas tas li, 8.314 J/(mol·K);

Thuab cua- Atmospheric kub,℃;

B- Blower conversion coefficient, npaum li 29.7;

- Cov nqi hluav taws xob tshwj xeeb ntawm cov roj, coj mus li 0.283;

η- Combined efficiency ntawm lub cev muaj zog thiab blower, coj li tas li 0.8;

Pi- Blower intake siab, Pa;

Z- Immersion dej siab ntawm diffuser, Pa;

Ppoob- Kev poob siab ntawm qhov zoo npuas diffuser nws tus kheej, Pa;

hL- Kev poob siab ntawm huab cua hauv cov kav dej, Pa.

 

Raws li kev sim, tus nqi ntawm cov pa xa mus rau hauv dej hauv ib chav tsev hluav taws xob siv los ntawm diffuser [kg / (kW·h)] yog Standard Aeration Efficiency (SAE), xws li hauvKev sib npaug (7). Tus nqi SAE tuaj yeem siv los ntsuas qhov kev siv tiag tiag ntawm qhov zoo npuas diffuser.

news-553-111

Qhov twg:

ASAE- Tus nqi ntawm SAE.

 

1.5 Cov Kev Ntsuas Qhov Ntsuas Qhov Ntsuas

Cov qauv cawv sib xyaw tau lim los ntawm cov ntawv lim zoo. Soluble CODCr(SCODCr), ammonia nitrogen, NO ₃--N, thiab TP raug ntsuas los ntawm cov txheej txheem hauv tebchaws.

 


 

2. Cov txiaj ntsig thiab kev sib tham

 

2.1 Kev tshem tawm cov pa phem

Qhov muaj txiaj ntsig zoo ntawm cov pa phem hauv lub caij ntuj sov thiab lub caij ntuj no ntawm WWTP tau qhia hauvDaim duab 3. Qhov nruab nrab kev kho mob ntws nyob rau lub caij ntuj sov thiab lub caij ntuj no yog 3.65 × 10⁵ m³ / d thiab 3.13 × 10⁵ m³ / d, raws li.Lub caij ntuj sov influent CODCrthiab ammonia nitrogen concentration yog (188.38 ± 52.53) mg / L thiab (16.93 ± 5.10) mg / L, raws.Lub caij ntuj no muaj kev cuam tshuam CODCrthiab ammonia nitrogen concentration yog (187.94 ± 28.26) mg / L thiab (17.91 ± 3.42) mg / L, raws. Lub caij ntuj sov nag ntau dua ua rau WWTP ua haujlwm hauv "siab hydraulic load - low pollutant load" mode. Qhov nce hauv hydraulic load shortens lub system HRT, txo lub sij hawm cov tshuaj tiv thaiv nyob rau hauv cov roj ntsha tank thiab cuam tshuam cov pa phem tshem tawm. Tsis tshua muaj pa paug paug load hauv WWTPs tuaj yeem yooj yim ua rau cov sludge loading tsawg heev, ua rau dhau - aeration thiab sludge disintegration. WWTPs yuav tsum tau kho raws sij hawm kho sludge loading thiab cua mov nqi kom txo tau qhov cuam tshuam ntawm kev ua haujlwm tsis muaj pa phem.Lub caij ntuj sov dej kub yog (27.32 ± 1.34) degree, ho siab tshaj lub caij ntuj no kub ntawm (17.39 ± 0.75) degree. Qhov kub thiab txias yog ib qho tseem ceeb cuam tshuam rau lub peev xwm tshem tawm cov pa phem ntawm lub cev. Kev ua siab ntev ntawm cov kab mob filamentous yog siab dua li ntawm floc- tsim cov kab mob, ua rau lawv nquag proliferate nyob rau hauv qis - qhov kub thiab txias ib puag ncig, ua rau sludge bulking. Cov cua kub qis kuj txo cov enzyme kev ua ntawm cov kab mob hauv cov activated sludge, txo cov substrate degradation tus nqi thiab endogenous respiration rate, ua rau txo cov pa phem tshem tawm efficiency. WWTPs tuaj yeem siv cov kev ntsuas xws li kev nce sludge hnub nyoog thiab MLSS hauv lub tank lom neeg kom txo tau qhov tsis zoo ntawm qhov kub thiab txias ntawm kev tshem tawm cov pa phem. Raws li lub hydraulic load nyob rau hauv lub caij ntuj no yog qis dua nyob rau hauv lub caij ntuj sov, lub HRT nyob rau hauv lub aerobic tank yog me ntsis txuas nrog txaus aeration, offsetting qhov tsis zoo ntawm qhov kub thiab txias ntawm nitrification. Yog li, cov dej ntws zoo nyob rau lub caij ntuj sov thiab lub caij ntuj no ua tau raws qib A tus qauv ntawm GB 18918-2002.

news-779-1019

 

2.2 Variation Patterns of Pollutant Forms raws Aerobic Tank

Nyob rau hnub xeem,tus muaj zog SCODCrThaum lub caij ntuj sov thiab lub caij ntuj no yog 186.76 mg / L thiab 248.42 mg / L, feem, thiab ammonia nitrogen concentration yog 22.05 mg / L thiab 25.91 mg / L., raws. Tej zaum vim yog kev sib xyaw ua ke ntawm cov kav dej ntws thiab cov dej hauv av nkag mus, qhov ua tau zoo tau qis dua qhov tsim nyog tus nqi. Kev hloov pauv ntawm cov pa phem raws lub tank aerobic tau qhia hauvDaim duab 4.

news-1100-600

Vim tias phosphorus tso tawm hauv lub tank anaerobic, denitrification hauv lub tank anoxic, thiab dilution los ntawm sludge rov qab, cov pa phem concentration txo qis ua ntej nkag mus rau hauv lub tank aerobic. SCODCrQhov concentration ntawm aerobic tank inlet nyob rau lub caij ntuj sov thiab lub caij ntuj no yog 30.32 mg / L thiab 52.48 mg / L, raws li, thiab ammonia nitrogen concentration yog 3.90 mg / L thiab 4.62 mg / L, raws li. Lub TN concentrations ntawm lub aerobic tank inlet nyob rau hauv lub caij ntuj sov thiab lub caij ntuj no yog 4.86 mg / L thiab 6.16 mg / L, raws li txoj cai, txo me ntsis rau 4.46 mg / L thiab 5.70 mg / L nyob rau hauv lub effluent, qhia ib tug kuj tsawg feem ntawm ib txhij nitrification thiab denitrification tshwm sim nyob rau hauv lub tank. SCODCrconcentration tau txo qis hauv cheeb tsam 1 txog 19.36 mg / L thiab 30.20 mg / L nyob rau lub caij ntuj sov thiab lub caij ntuj no, feem; ammonia nitrogen concentration txo mus rau 1.75 mg / L thiab 2.80 mg / L. Qhov kev txo qis ntawm cov pa phem concentration qeeb qeeb hauv Zone 2, qhia tias me me molecular organic teeb meem tau degraded tag nrho thiab nitrification tiav. Cov pa phem concentration ntawm qhov kawg ntawm Cheeb Tsam 2 twb tau raws li tus qauv effluent paug. Cov pa phem concentration tseem yuav luag tsis hloov pauv hauv Zone 3, tab sis DO tus nqi hauv cov cawv sib xyaw tau nce, qhia tias feem ntau ntawm cov pa oxygen nkag rau hauv cheeb tsam no yaj mus rau hauv cov sludge tov cawv thiab tsis siv rau COD.Croxidation thiab ammonia oxidation. SCOD effluentCrQhov concentration ntawm aerobic tank nyob rau lub caij ntuj sov thiab lub caij ntuj no yog 15.36 mg / L thiab 26.51 mg / L, raws li, thiab cov effluent ammonia nitrogen concentrations yog 0.17 mg / L thiab 0.50 mg / L, raws li.Kev tshem tawm ammonia nitrogen ntau dua nyob rau lub caij ntuj sov yog vim dej kub ntau dua txhim kho cov nitrification- denitrification kev ua ntawm cov kab mob.. Zhang Tao et al. pom tiasLub caij ntuj no tsis tshua muaj kub txo qhov nplua nuj ntawm ammonia-oxidizing kab mob thiab nitrite-oxidizing kab mob, txo cov ammonia nitrogen tshem tawm tus nqi hauv WWTPs.

 

2.3 Tawm-Cov txiaj ntsig kuaj roj raws li Aerobic Tank

Kev sim teb ntawm kev hloov pauv cov pa oxygen ntawm cov npuas zoo aeration tau ua raws li lub tank aerobic thaum lub caij ntuj sov thiab lub caij ntuj no siv lub off-gas analyzer. Cov txiaj ntsig tau qhia hauvDaim duab 5. Qhov DO concentration nyob rau hauv lub tank aerobic maj mam nce raws cov kev taw qhia ntws. Qhov DO concentration hauv cov cawv sib xyaw yog nyob ntawm tus nqi ntawm cov pa xa tawm los ntawm cov pa roj mus rau theem ua kua los ntawm cov diffusers (piv txwv li, OTR) thiab cov pa oxygen siv los ntawm cov kab mob (piv txwv li, peb). Lub substrate muaj ntau nyob rau pem hauv ntej kawg ntawm lub aerobic tank, thiab microorganisms xav tau oxygen ntau dua rau degrade lub substrate. Yog li ntawd, DO concentration yog qis tshaj nyob rau hauv cheeb tsam 1 nyob rau lub caij ntuj sov thiab lub caij ntuj no, ntawm (1.54 ± 0.22) mg / L thiab (1.85 ± 0.31) mg / L, feem. DO concentration tau nce mus rau (2.27 ± 0.45) mg / L thiab (2.04 ± 0.13) mg / L hauv Zone 2, feem. Hauv cheeb tsam 3, DO concentration yog (4.48 ± 0.55) mg / L thiab (4.53 ± 1.68) mg / L, raws li. Cov qauv sib txawv ntawm DO raws txoj kev yog zoo ib yam nrog cov pa phem concentration. Organic teeb meem degradation thiab nitification tau pib ua tiav hauv Zone 2. Cov ntsiab lus ntawm cov organic hauv Zone 3 yog qis dua, txo qis cov pa oxygen, ua rau cov pa oxygen tsis tau siv tag nrho thiab khaws cia rau hauv cov dej theem li DO, ua rau DO concentration nce mus rau qib siab heev. Qhov nruab nrab DO hauv Cheeb Tsam 3 yog qhov siab dua 2.0 mg / L, qhia tias tshaj - aeration ntawm qhov kawg ntawm lub tank aerobic. Endogenous respiration ntawm activated sludge txo cov sludge kev ua si thiab tuaj yeem ua rau sludge bulking yooj yim, thaum tseem nkim zog. Qhov siab tshaj DO concentration ntawm qhov kawg ntawm lub tank aerobic kuj ua rau ntau dua DO concentration nyob rau hauv cov cawv rov qab, uas tsis tsuas yog nce DO concentration nkag mus rau hauv lub tank anoxic ntawm sab nraud reflux tab sis kuj txo cov nqi ntawm COD Cr, yog li txo denitrification efficiency. Yog li ntawd, nws raug pom zoo kom txo cov cua hauv Cheeb Tsam 3, tswj tsuas yog qhov tsim nyog sib xyaw, kom txuag tau aeration zog noj.

news-619-1004

Raws li qhia hauvDaim duab 5, qhov sib txawv tseem ceeb muaj nyob rau hauv kev ua haujlwm ntawm cov pa oxygen ntawm diffusers nyob rau hauv ntau txoj kev thaum lub caij ntuj sov thiab lub caij ntuj no. Qhov nruab nrab OTE ntsuas nyob rau lub caij ntuj no yog 9.72%, qis dua qhov txiaj ntsig ntsuas lub caij ntuj sov (16.71%). Qhov no yog vimKev txo qis hauv dej kub txo cov kev ua ntawm cov kab mob hauv lub tank aerobic ntawm WWTP, ua rau txo qis kev siv cov pa oxygen.. Tom qab kho qhov kub thiab txias, salinity, thiab DO, qhov nruab nrab SOTE qhov tseem ceeb nyob rau lub caij ntuj sov thiab lub caij ntuj no yog 17.69% thiab 14.21%, feem. Lub caij ntuj sov SOTE tau me ntsis siab dua thaum lub caij ntuj no, tej zaum vimua haujlwm ntev exacerbated diffuser fouling, thaiv qhov pores, thiab txo cov pa oxygen hloov kev ua haujlwm ntawm diffuser.

 

2.4 Kev Tshawb Fawb Txog Kev Txhim Kho Zog Muaj Peev Xwm rau Aerobic Tank Aeration System

Raws li qhov sib npaug (3) thiab (4), qhov xav tau ntawm cov pa oxygen, cov pa oxygen, thiab lub tshuab hluav taws xob rau txhua qhov chaw ntawm lub tank aerobic nyob rau lub caij ntuj sov thiab lub caij ntuj no tau xam, raws li qhia hauvRooj 2. Tag nrho cov pa oxygen xav tau ntawm lub tank aerobic nyob rau lub caij ntuj no yog kwv yees li 34.91% siab dua nyob rau lub caij ntuj sov, tshwm sim los ntawm COD muaj zog dua.Crthiab ammonia nitrogen pollutant load nyob rau lub caij ntuj no piv rau lub caij ntuj sov. Cov pa oxygen xav tau nyob rau hauv txhua cheeb tsam ntawm lub tank aerobic txo qis vim tias cov pa phem cuam tshuam los ntawm txoj kev. Zone 1 muaj cov pa phem ntau tshaj plaws thiab txaus substrate, ua rau muaj kev ua haujlwm microbial ntau dua, yog li nws cov pa oxygen xav tau ntau tshaj. Raws li cov pa phem tsis tu ncua, cov pa oxygen xav tau hauv Zone 2 thiab Zone 3 maj mam txo. Nyob rau lub caij ntuj sov, cov pa oxygen xav tau ntawm peb thaj chaw yog 72.62%, 21.65%, thiab 5.73% ntawm tag nrho cov pa aerobic tank xav tau, feem. Nyob rau lub caij ntuj no, qhov sib piv yog 72.84%, 24.53%, thiab 2.63%, feem. Hauv cov pa activated sludge reactors, cov pa oxygen xav tau rau sab pem hauv ntej yog 45% -55%, ntu nruab nrab 25% -35%, thiab sab nraub qaum 15% -25%. Kev kho mob ntawm qhov kawg ntawm lub tank aerobic yog qis dua li cov txiaj ntsig zoo. Cov huab cua nyob rau hauv pem hauv ntej kawg yuav raug txo kom tsim nyog, tso cai rau qee cov pa phem kom degraded nyob rau hauv lub rear seem.

news-1000-500

Piv rau lub caij ntuj sov,Cov pa oxygen xav tau ntawm cov txheej txheem kev kho mob lom nyob rau lub caij ntuj no yog siab dua, thiab cov pa oxygen hloov mus rau qhov zoo ntawm cov npuas aeration yog qis dua, ua rau kom muaj huab cua ntau dua.. Raws li cov ntaub ntawv ua haujlwm ntawm WWTP, tag nrho cov cua tshuab cua hauv lub caij ntuj sov thiab lub caij ntuj no yog 76.23 m³ / h thiab 116.70 m³ / h, feem. Cov pa cua tau siab tshaj plaws hauv Cheeb Tsam 1, thaum huab cua nyob hauv Zone 2 thiab Zone 3 zoo sib xws tab sis qis dua hauv Cheeb Tsam 1. Cov pa oxygen thaum lub caij ntuj sov yog 38.99% siab dua li qhov xav tau oxygen, qhia tias lub zog tseem ceeb -txuag muaj peev xwm. Cov pa oxygen nyob rau hauv Zone 2 thiab Zone 3 tau tshaj qhov xav tau oxygen tiag tiag. Cov pa oxygen thaum lub caij ntuj no yog 7.07% siab dua li qhov xav tau oxygen. Cov pa oxygen thiab kev xav tau hauv Zone 1 thiab Zone 2 tau sib npaug, thaum dhau - aeration tshwm sim hauv Cheeb Tsam 3. Lub tshuab hluav taws xob yog qhov sib npaug rau cov khoom siv huab cua, xws li hauv Kev Sib Tw (6). Lub zog noj ntawm lub tshuab cua nyob rau lub caij ntuj sov thiab lub caij ntuj no yog 85.21 kW thiab 130.44 kW, feem. Henkel qhia qhov ntawdqhov nce hauv huab cua kub txo lub zog ntawm cov tshuab tshuab hauv cov tshuab aeration. Hauv kev teb rau qhov sib txawv ntawm cov pa oxygen xav tau ntawm cov channel sib txawv, WWTPs yuav tsum ua raws li cov kev hloov kho aeration, xws li tapered aeration. Qhov no tuaj yeem cuam tshuam tag nrho qhib cov kav hlau xa hluav taws xob nyob rau pem hauv ntej kawg, qhib cov nyob nruab nrab ntawm ib nrab, thiab kho cov ceg kav dej thaum kawg mus rau qhov tsawg kawg nkaus qhib rautxuag huab cua thiab aeration zog noj.

 

Ntxiv rau qhov kev siv tiag tiag ntawm cov npuas zoo diffusers, Standard Aeration Efficiency (SAE) hauv lub tank aerobic lub caij ntuj sov yog 2.57 kg O₂ / kW·h, uas yog 32.29% siab dua thaum lub caij ntuj no. Qhov sib txawv ntawm cov dej muaj txiaj ntsig zoo, muaj nuj nqis, thiab qhov kub thiab txias ntawm lub caij ntuj sov thiab lub caij ntuj no ua rau muaj kev hloov pauv loj hauv kev ua haujlwm thiab kev tswj hwm lub tshuab aeration hauv WWTP. Lub zog pov tseg tau hnyav dua nyob rau lub caij ntuj sov dua li lub caij ntuj no, thiab lub tshuab aeration tau ua tiav cov khoom siv zoo dua - qhov xav tau sib npaug hauv lub caij ntuj no. Xav txog qhov muaj zog txaus tus nqi thiab zoo,huab cua yuav raug txo kom tsim nyog thaum lub caij ntuj sovthaum kom ntseeg tau cov dej ntws zoo thiab kev sib xyaw txaus hauv lub tank aerobic. Nyob rau lub caij ntuj no, txhawm rau txo qhov cuam tshuam ntawm cov khoom muaj kuab paug siab thiab qis qis, yuav tsum tau ua kom muaj aeration txaus. Txawm li cas los xij, nws yog ib qho tseem ceeb uas yuav tsum nco ntsoov tias thaum lub sij hawm ua haujlwm ntev -, cov pa phem nyob rau ntawm qhov chaw thiab sab hauv lub qhov hws ntawm cov diffusers, maj mam thaiv lub qhov hws, thiab cov pa oxygen hloov pauv yuav txo qis. Yog tias kev tu lub diffuser tsis raws sijhawm, nws tuaj yeem ua rau cov pa oxygen tsis txaus los ntawm lub tshuab aeration, cuam tshuam rau cov dej tsis zoo.

 

WWTP siv DO-blower air flow control tswv yim. Lub hom phiaj ntawm lub tshuab aeration tswj yog los muab qhov chaw ruaj khov DO rau cov kab mob hauv lub tank aerobic thiab xyuas kom muaj kev ua raws li cov dej ntws tawm. Txawm li cas los xij, DO cov lus tawm tswv yim ib leeg tsis tuaj yeem ntsuas lub zog - txuag lub peev xwm ntawm lub tshuab aeration. Kev ntsuam xyuas cov pa oxygen hloov pauv ntawm lub tshuab aeration tso cai rau kev xam cov pa oxygen tiag tiag ntawm lub tshuab aeration thiab piav qhia nws qhov kev hloov pauv ntawm txoj hauv kev. Ua ke nrog cov ntaub ntawv xav tau cov pa oxygen, qhov no ua rau muaj kev tswj hwm ntawm lub tshuab aeration kom ua tiav cov khoom siv - qhov xav tau sib npaug thiab lub hom phiaj ntawm kev txuag hluav taws xob thiab kev txo qis.

 


 

3. Cov lus xaus

 

  • Cov dej kub hauv lub caij ntuj sov siab dua txhim kho microbial nitrification kev ua si thiab denitrification, ua rau ntau dua COD Cr thiab ammonia nitrogen nyob rau lub caij ntuj no piv rau lub caij ntuj sov. Txawm li cas los xij, vim tias qis hydraulic load nyob rau lub caij ntuj no tshaj lub caij ntuj sov, qhov txuas ntxiv HRT nyob rau hauv lub tank aerobic thiab txaus aeration offset qhov tsis zoo ntawm qhov kub thiab txias ntawm nitrification. Yog li ntawd, effluent zoo nyob rau hauv ob lub caij ntuj sov thiab lub caij ntuj no tau raws li cov Qib A tus qauv ntawm GB 18918-2002.

  • Piv nrog rau lub caij ntuj sov, cov pa oxygen xav tau ntawm cov txheej txheem kev kho mob lom nyob rau lub caij ntuj no yog siab dua, cov pa oxygen hloov mus rau qhov zoo ntawm cov npuas aeration yog qis dua, ua rau cov cua xav tau ntau dua thiab qis dua aeration efficiency.

  • Cov pa oxygen thaum lub caij ntuj sov thiab lub caij ntuj no yog 38.99% thiab 7.07% siab dua li qhov xav tau oxygen, raws li qhov qhia tau tias muaj zog ntau dua -txuag lub peev xwm thaum lub caij ntuj sov. Cov pa phem concentration txo qis zuj zus raws li lub tank aerobic, tshuav yuav luag tas li thaum kawg, thaum lub DO concentration ntawm qhov kawg yog ntau dua nyob rau pem hauv ntej. Qhov no qhia tau hais tias feem ntau ntawm cov pa oxygen muab thaum kawg dissolves rau hauv cov sludge tov cawv thiab tsis siv rau COD.Croxidation thiab ammonia oxidation, tawm tswv yim tshaj - aeration. Yog li ntawd, cov khoom cua ntawm qhov kawg ntawm lub tank aerobic tuaj yeem raug txo kom tsim nyog thaum ua kom cov dej ntws zoo thiab sib tov txaus.